BS 5839-1 L2CompliantASSET-012 · Cyclic Fix Verification · Meridian Offices · design D-350
Installed
10 Jun 2020
Last serviced
5 Nov 2025
Devices
23
Replacement due
0
Device register
23 installed devices| Make / model | |||||
|---|---|---|---|---|---|
| Optical Smoke | Apollo Orbis Optical | Ground floor | SN-D-350-OPTI-001 | 5 Nov 2025 | OK |
| Optical Smoke | Hochiki ESP Optical | First floor | SN-D-350-OPTI-002 | 5 Nov 2025 | OK |
| Optical Smoke | Gent S-Quad Optical | Second floor | SN-D-350-OPTI-003 | 5 Nov 2025 | OK |
| Optical Smoke | Apollo Orbis Optical | Third floor | SN-D-350-OPTI-004 | 5 Nov 2025 | OK |
| Optical Smoke | Hochiki ESP Optical | Fourth floor | SN-D-350-OPTI-005 | 5 Nov 2025 | OK |
| Optical Smoke | Gent S-Quad Optical | Fifth floor | SN-D-350-OPTI-006 | 5 Nov 2025 | OK |
| Optical Smoke | Apollo Orbis Optical | Plant room | SN-D-350-OPTI-007 | 5 Nov 2025 | OK |
| Optical Smoke | Hochiki ESP Optical | Reception | SN-D-350-OPTI-008 | 5 Nov 2025 | OK |
| Optical Smoke | Gent S-Quad Optical | Corridor | SN-D-350-OPTI-009 | 5 Nov 2025 | OK |
| Optical Smoke | Apollo Orbis Optical | Store room | SN-D-350-OPTI-010 | 5 Nov 2025 | OK |
| Optical Smoke | Hochiki ESP Optical | Roof | SN-D-350-OPTI-011 | 5 Nov 2025 | OK |
| Optical Smoke | Gent S-Quad Optical | Ground floor | SN-D-350-OPTI-012 | 5 Nov 2025 | OK |
| Multi-sensor | Apollo Discovery Multisensor | First floor | SN-D-350-MULT-001 | 5 Nov 2025 | OK |
| Multi-sensor | Gent S-Quad Multisensor | Second floor | SN-D-350-MULT-002 | 5 Nov 2025 | OK |
| Multi-sensor | Apollo Discovery Multisensor | Third floor | SN-D-350-MULT-003 | 5 Nov 2025 | OK |
| Manual Call Point | C-TEC Call Point CP3 | Fourth floor | SN-D-350-MCP-001 | 5 Nov 2025 | OK |
| Manual Call Point | Apollo Orbis MCP | Fifth floor | SN-D-350-MCP-002 | 5 Nov 2025 | OK |
| Sounder + VAD | Hochiki Sounder Beacon | Plant room | SN-D-350-SOUN-001 | 5 Nov 2025 | OK |
| Sounder + VAD | C-TEC Combined Sounder VAD | Reception | SN-D-350-SOUN-002 | 5 Nov 2025 | OK |
| Sounder + VAD | Hochiki Sounder Beacon | Corridor | SN-D-350-SOUN-003 | 5 Nov 2025 | OK |
| Sounder + VAD | C-TEC Combined Sounder VAD | Store room | SN-D-350-SOUN-004 | 5 Nov 2025 | OK |
| I/O Interface | Apollo I/O Interface Unit | Roof | SN-D-350-INTE-001 | 5 Nov 2025 | OK |
| I/O Interface | Gent Interface Module | Ground floor | SN-D-350-INTE-002 | 5 Nov 2025 | OK |
Service history
Service visit
Routine service — all devices tested.
5 Nov 2025 · James Taylor
Inspection
Visual inspection — no structural or occupancy changes affecting conformity.
6 Oct 2025 · James Taylor
Certificate
BS 5839-1 commissioning certificate issued.
10 Jun 2020 · Andy Griffey
Install
System commissioned and handed over (design D-350).
10 Jun 2020 · Andy Griffey